Product description
Marlon TurboFlow 20 is a cement-based, fast-setting liquid mortar for cementing work requiring a short setting time and fast strengthening. Marlon TurboFlow 20 is composed of special fast-setting cement, contraction-reducing additives and oven-dried silica sand with a controlled grain size. Ready for use after clean water is added and the mixture is mixed effectively.
- Versatile, pre-mixed liquid mortar
- Very fast setting and high, early strength
- Contraction-compensated
- Requires only the addition of water
Marlon TurboFlow 20 is typically used for filling work, where a fast-curing, workable liquid mortar is needed. Not for use in bearing building parts.
Mixing with the specified amount of water produces a liquid mortar with good flow and workability. Marlon TurboFlow 20 can be poured directly out into the area or the mould to be filled. Marlon TurboFlow 20 achieves a relatively high strength in just a few hours.
Before repair or pouring work can begin, you must ensure a suitable and solid underlying surface free of loose particles and cleaned of any cement slurry, oil or other impurities. If the underlying surface is absorbent, you must water the surface to achieve a suitably absorbent surface, to achieve the greatest possible adhesion.
Marlon TurboFlow 20 must be used immediately after mixture, as the setting process is far faster than with traditional mortars. The opening time is approx. 10-15 min at +20°C. Higher temperatures will shorten, and higher temperatures will lengthen both the processing and hardening times. For larger cementation projects, consideration must be given to contraction and expansion joints according to the same guidelines as for ordinary concrete pouring. Adding more water than described will reduce the strength and curing time and increase the tendency towards contraction cracks. Marlon TurboFlow 20 is generally used for thicknesses of 10-150 mm.
Newly poured liquid mortar must be protected from fast drying the first 12-15 hours with the help of tight-sealing plastic film, sealer or another suitable and approved method.
Casting should not take place at temperatures under +5°C. Marlon TurboFlow 20 does not tolerate frost in the setting and curing periods.
Clean equipment, machinery and tools with water immediately after use. Hardened TurboFlow 20 can only be removed mechanically.
Marlon TurboFlow 20 is subject to internal inspection according to Marlon’s quality assurance system. Subsequent measuring and mixing at the site of application is not included in quality control.
Manufacturer
Marlon Tørmørtel A/S
Virkelyst 20
DK-8740 Brædstrup
Filler material
Oven-dried and sorted silica sand, cl. E.
Material type
Fast-curing, cement-based liquid mortar.
Cement type
Portland/aluminate cement.
Added water
Approx. 3.6 to 3.8 l per 25 kg.
Consumption
Approx. 2.0 kg per m² at a thickness of 1 mm.
Opening time
Approx. 10-15 minutes, depending on the temperature.
Layer thickness
Guideline, approx. 10-150 mm.
Yield
1 kg liquid mortar corresponding to approx. 0.5 l wet mortar.
Storage
9 months in dry and suited conditions in unopened packaging.
Packaging
25 kg plastic sacks or big bags.
Technical data | Values | Method |
Compressive strength, 1 hour | > 5 MPa | DS/EN 12190 |
Compressive strength, 4 hours | > 10 MPa | DS/EN 12190 |
Compressive strength, 7 days | > 40 MPa | DS/EN 12190 |
Compressive strength, 28 days | > 60 MPa | DS/EN 12190 |
Bending tensile strength, 28 days | > 9 MPa | DS/EN 12190 |
Density (wet) | Approx. 2000 kg/m³ | DS/EN 423.16 |
Chromate content | < 2 mg/kg cement | |
Chloride content | < 0.003 weight % | TI-B 9 |
Information | ||
Item no. | 10309 | |
Pr no. | Application pending | |
Version | 04.14 - |
|
Marlon Tørmørtel A/S Virkelyst 20 8740 Brædstrup Year 15 DoP 1000309 |
EN 1504-3 1073-CPR-171-01 Concrete repair product for construction repairs. CC mortar based on hydraulic cement. |
Compressive strength | > 45 MPa Class R4 |
Chloride content | ≤ 0.05 % |
Adhesion | ≥ 2.0 MPa |
Carbonatization | Passed |
Elastic modulus | ≥ 20 GPa |
Thermal compatibility | Part 1 ≥ 2.0 MPa |
Capillary absorption | ≤ 0.5 kg x m-2 x h-5 |
Hazardous substances | In accordance with section 5.4 |
Fire-resistance | Class A1 |